Big sensor performance in a small sensor package
Smart, safe, innovative and versatile solution
- Assemble your own customized system from a variety of temperature ranges and network communication interfaces
- Reduce maintenance with self diagnostic features to prevent cable breakage and internal overheating
- Available with intrinsically safe ATEX / IECEx certification for explosive environments
Description
The Raytek MI3 digital infrared thermometer represents a new generation of performance and innovation in continuous noncontact temperature monitoring for a broad range of OEM applications and manufacturing processes. Each MI3 infrared temperature thermometer is a two piece system with a miniature sensing head and separate communications electronics. The miniature sensing head can be installed in any system and outperforms much larger sensors, making the Raytek MI3 the best valued IR temperature sensor in its class.
The OEMMI3 version of this digital infrared thermometer allows direct digital communication with the host machine controller without the need for an additional communication box.
The innovative multiple sensing head interface, which can support up to 8 individually addressable heads per communication box, reduces sensor cost, simplifies sensor installation and applications troubleshooting, and provides the lowest cost per measurement point.
Explosive atmospheres at the workplace can be caused by flammable gases, mists or vapors, or by combustible dust. Raytek MI3 ATEX/IECEx certified sensors can be used safely to monitor the right temperature in such explosive processes. All standard MI3 and MI3100 heads can be ordered with optional ATEX/IECEx certification. One specifically provided Ex-proof power supply can be used with 2 sensing heads.
The MI3 infrared thermometer is also available in a convenient DIN-rail mountable package standard with USB digital communications, as well as RS485, Profibus, Modbus, Profinet and Ethernet options. The DIN mountable communication box supports up to 8 heads and provides 4 galvanic isolated analog outputs.
Key Features:
- Read temperature ranges from -40 to 1800°C (-40 to 3272°F)
- Withstand ambient temperatures up to up to 180 °C (356 °F) without cooling
- Accessories for cooling and air purging
- Response time: 130 mSec and 20 mSec on on standard models, 10 mSec on MI3100 model
- Optical resolution: 22:1 on standard models, 100:1 on MI3100 model
- Dedicated close focus lens for spot sizes down to 0.5 mm (0.02 in)
- Industrial rugged cable: Silicone and Halogen free, resistant against oil, bases, and acids
- No cable bending/moving effects, allowing continuous reliable measurement in moving installations (robotic arms, linear drives, chains, etc.)
- Self diagnostic features: break of a head wire, head internal temperature
- Plug & Play exchangeability for sensing heads (no heads parameter anymore; Raytek patent)
- Robust EMI immunity due to digital head-to-box communication
- DataTemp Multidrop software compatible
- Sensor status/self diagnostic LED indicator
Technical Specifications
General Specifications
Model Number | MI3-LT (Low Temp) | MI3-G5 (Glass) | MI3-2M | MI3-1M |
---|---|---|---|---|
Temperature Range |
LTS02, LTS10, LTH10 -40 to 600° °C (-40 to 1112° ºF) LTS20, LTF, LTH20 0 to 1000 ºC (32 to 1832 ºF) |
250 to 1650 ºC (500 to 3000 ºF) |
250 to 1400 ºC (500 to 2552 ºF) |
500 to 1800 ºC (932 to 3272 ºF) |
Spectral Response | 8 to 14 μm | 5 μm | 1.6 μm | 1.0 μm |
System Accuracy | ±1% of reading or ±1°C (2°F)* @23°C ±5°C (73°F ±9°F) | ± (0.5% of reading + 2°C) | ||
Repeatability | ±0.5% of measured value or ±0.5°C (1°F)* | ± (0.25% of reading + 1°C) | ||
Optical Resolution (D:S) |
LTS - 2 : 1, 10 : 1, 22 : 1 LTH - 10 : 1, 22 : 1 LTF - 10 : 1 |
10 : 1 | 100 : 1 | 100 : 1 |
Response Time |
LTS, LTH - 130 ms LTF - 20 ms |
130 ms | 10 ms | |
Temperature Coefficient | ± 0.05 K / K or ± 0.05% / K of reading* | ± 0.01% / K of reading | ||
Emissivity | 0.100 to 1.100 for all models | |||
Signal Processing | Peak hold, valley hold, adjustable up to 998 s variable averaging filter |
Electrical Specifications - MI3 Box
Outputs | 4 – 20 mA, 0 – 20 mA, 0 – 5 V, or 0 – 10 V; J, K, R, or S thermocouple; 0 – 5 V head ambient signal |
Thermocouple |
J: -40 to 600°C (-40 to 1112°F) K: -40 to 800°C (-40 to 1472°F) R/S: 250 to 1800°C (482 to 3272°F) |
Communications |
USB 2.0 RS485 Profibus DP-V0 Profinet IO Ethernet TCP/IP, http and 64 MB data logger Modbus RTU |
Power Supply | 8 to 32 VDC, 5 W |
Environmental Protection | IP65 (NEMA 4) |
Environmental
Ambient Temperature |
LT, G5: -10 to 120 °C (14 to 248 °F) LTH: -10 to 180 °C (14 to 356 °F) 1M, 2M: 0 to 120 °C (32 to 248 °F) Laser 1M, 2M: automatic switch off at 65°C (149°F) |
Storage Temperature |
LTH: -20 to 180°C (-4 to 356°F) all other models: -20 to 120°C (-4 to 248°F) |
Environmental Rating | IP65 (NEMA-4) / IEC 60529 |
EMC | EN 61326-1:2006 |
Standards and Compliance
EC Directive 2014/30/EU | EMC |
EC Directive 2011/35/EU | Low Voltage - valid for device: Ex Power Supply xxxMI3ACIS |
EC Directive 2011/65/EU | RoHS Compliance amended by Directive (EU) 2015/863 |
EC Directive 2014/34/EU | ATEX valid for device: xxxMI3xxxISx, xxxMI330xxxISx, xxxMI3100xxxISx, xxxMI3xxLTHISx, xxxMI3ACIS |
EC Directive Nr. 1907/2006 | REACH amended by Directive (EU) 2020/2096 |
EN 61326-1: 2013 | Electrical measurement, control and laboratory devices - Electromagnetic susceptibility (EMC) |
EN 61558-1: 2006 | Safety Requirements for power transformers, power supplies, reactors and similar products (low voltage) |
EN 61558-2-6: 2010 | Safety Requirements for power transformers, power supplies, reactors and similar products for use up to 1.1 kV (low voltage) |
EN 50581: 2012 | Technical documentation for the evaluation of electrical products with respect to restriction of hazardous substances (RoHS) |
EN 60079-0: 2019 | Risk of explosion – part 0: general requirements (ATEX) |
EN 60079-11: 2012 | Risk of explosion – part 11: device protection by intrinsic safety “I” (ATEX) |
UKCA | Conforms to UK Conformity. Except for units with intrinsically-safe rating. |
KCC | Electromagnetic Compatibility applies to use in Korea. This product meets requirements for industrial (Class A) electromagnetic wave equipment. |
Applications
- Paper Processing and Converting, such as cardboard production
- Semiconductor Production, such as Polysilicon Growing, Crystal Growing, and Wafer Polishing
- Metals Processing
- Plastic Processing
- Glass Processing
Accessories
Each MI3 sensor system is comprised of (1) MI3 sensing head and (1) MI3COMM or MI3MCOMM communication module. The sensing head includes one mounting nut and 1m (3.3ft) cable. Longer cables up to 30 m (100ft) maximum are available and must be specified at time of order. The MI3 sensing head and MI3COMM box are ordered as separate items. Additional accessories are listed below:
Accessories for MI3 Sensing Heads
- Adjustable Bracket (LT, G5: XXXMIACAB / 1M, 2M: XXXMI3100ADJB)
- Fixed Bracket (LT, G5: XXXMIACFB / 1M, 2M: XXXMI3100FB)
- Isolation Kit for Fixed Bracket (1M, 2M: XXXMI3100ISOKIT)
- Air Purge (LT, G5: XXXMIACAJ / 1M, 2M: XXXMI3100AP)
- Air Cooling Jacket (XXXMIACCJ: 0.8 m/2.6 ft, XXXMIACCJ1: 2.8 m/9.2 ft)for ambient temperatures up to 200°C/392°F (LT, G5 only)
- Close Focus Lens (LT, G5: XXXMI3ACCFL))
- Protective Window (LT, G5: XXXMIACPW / 1M, 2M: XXXMI3100PW)
- *Optional longer head cable lengths: 3 m, 8 m, 15 m, 30 m (9.8, 26, 49, 98 ft.)
- *Optional water cooled housing (1M, 2M heads)
- *Optional Networkable OEM sensing head without the need for a box
Accessories for MI3 Box
- Multi-Channel Box to support up to 8 sensing heads in a network (XXXMICONNBOX)
- USB/RS485 Adapter for boxes with RS485 interface (XXXUSB485)
- *Optional Fieldbuses for Comm Box: RS485, Profibus, Profinet, Ethernet, Modbus
- *Optional 4 analog output channels for Comm Box, DIN 6TE: mA or V, all channels electrically isolated
Downloads
Product Literature:
Manuals:
Success Stories: